Oleophobic borosilicate microfiber media provides exceptional dirt holding and drainage capabilities with low differential pressure
4.1 to 288 scfm
3/8” to 3” NPT
5 & 1 micron
The compact build allows close coupling of the filters to simplify installation and maintenance
A manual drain comes included as standard, with drain flask available as option
Filter Models |
Element Part No. |
Inlet & Outlet (1) |
Exhaust Flow Rate (Vacuum Displacement) (2) |
|
NPT |
scfm |
Nm3/h |
||
NPP 0035 (grade) |
E 0035 (grade) |
⅜” |
4.1 |
7 |
NPP 0050 (grade) |
E 0050 (grade) |
½” |
6.5 |
11 |
NPP 0070 (grade) |
E 0090 (grade) |
½” |
11.8 |
20 |
NPP 0085 (grade) |
E 0090 (grade) |
¾” |
14.7 |
25 |
NPP 0125 (grade) |
E 0135 (grade) |
¾” |
20.6 |
35 |
NPP 0135 (grade) |
E 0135 (grade) |
1” |
23.5 |
40 |
NPP 0175 (grade) |
E 0175 (grade) |
1” |
29.4 |
50 |
NPP 0280 (grade) |
E 0325 (grade) |
1 ¼” |
44.1 |
75 |
NPP 0325 (grade) |
E 0325 (grade) |
1 ½” |
50.0 |
85 |
NPP 0400 (grade) |
E 0450 (grade) |
1 ½” |
59.0 |
100 |
NPP 0450 (grade) |
E 0450 (grade) |
2” |
67.5 |
115 |
NPP 0700 (grade) |
E 0700 (grade) |
2” |
106 |
180 |
NPP 0850 (grade) |
E 1000 (grade) |
2 ½” |
118 |
200 |
NPP 1000 (grade) |
E 1000 (grade) |
3” |
138 |
235 |
NPP 1250 (grade) |
E 1250 (grade) |
3” |
212 |
360 |
NPP 1500 (grade) |
E 1500 (grade) |
3” |
288 |
490 |
Element Performance |
PP5 |
PP1 |
Particle Removal |
5 micron |
1 micron |
Maximum Oil Carryover at 68°F (ppm or mg/m3) |
1 mg/m3 |
1 mg/m3 |
Pressure Drop - Clean |
0.3 psid |
0.6 psid |
Pressure Drop - Recommended Replacement |
1.5 psid |
1.5 psid |
Recommended Operating Temperature Range |
35 to 212°F/ 2 to 100°C |
|
Design Operating Temperature Range |
35 to 248°F / 2 to 120°C |
|
Flow Direction Through Element |
Outside to Inside |
|
Maximum Element Life |
12 months or 8000 hours |
(1) inlet and outlet connections are NPT threaded to ANSI B2.1
(2) free air conditions when operating at atmospheric pressure. For vacuums refer to the vacuum correction factor table above
(3) models NPP 0070 to NPP 1500 can be adapted to use 1⁄4” drains with a reducer. Drain flasks are available for liquid collection for vacuum (or
atmospheric pressure) applications only
(4) technical specifications subject to change without notice. Direct inquiries to [email protected] or contact 704.897.2182