This nitrogen range provides a typical return on investment between 6 to 24 months
Plug-and-play system can be installed easily with minimum cost and interruption
Compact design allows installation in spaces too small for twin tower generator systems
Model |
Rated Outlet Flow (1) |
Nitrogen Purity at the Outlet (Max Oxygen Content) |
||||||
99.9% (0.10%) |
99.5% (0.50%) |
99% (1%) |
98% (2%) |
97% (3%) |
96% (4%) |
95% (5%) |
||
scfh |
49.4 |
77.7 |
95.4 |
130.7 |
162.5 |
187.2 |
208.4 |
|
scfh |
84.8 |
120.1 |
151.9 |
204.8 |
254.3 |
296.6 |
332.0 |
|
scfh |
141.3 |
197.8 |
250.7 |
339.0 |
423.8 |
490.9 |
547.4 |
Specifications |
|
Design operating pressure range |
87 to 145 psig / 6 to 10 bar |
Design operating temperature range |
41 to 122°F / 5 to 55°C |
Maximum inlet particulate |
0.1 micron |
Maximum inlet oil content |
0.01 micron (2) |
Maximum inlet dew point |
38°F PDP (3) |
Supply voltage |
100 - 240 VAC (50 or 60Hz) |
(1) at 100 psig inlet pressure and 68 - 77°F/20-25°C inlet temperature. For outlet flow at all other conditions refer to the correction factors above or contact support
(2) requires an upstream dryer. Contact nano for assistance selecting the optimum dryer for your application
(3) including oil vapor