Key Specs:

Purity

90 to 95%

Flow Rate

up to 19.3 scfh

Max Allowable Working Pressure

145 psig/ 10 barg

Product Documentation

ISO compressed air quality standards brochure

ISO Compressed Air Quality Standards

Filename
EN-ISO-brochure-compressed-air-quality-standards.pdf
Size
7 MB
Format
application/pdf
View
nano equipment user guide

N2 GEN2-MAX - User Guide

Filename
N2-EN-GEN2-MAX-user-guide-nitrogen-generators.pdf
Size
9 MB
Format
application/pdf
View
ga general arrangement drawing

N2 GEN2-MAX 5.5K

Filename
N2-GEN2-MAX-5.5K-ga-drawing-nitrogen-generator.pdf
Size
1 MB
Format
application/pdf
View

Features

Units include zirconium O2 sensor, O2 pressure regulator, control valve, and O2 flow meter as standard.

Start-up is simple with O2 purity control and automatic start-up features of the nano Vision01 controller.

The premium zeolite media is designed to last for the life of the unit. 

Specifications of our models

Generator Model

Rated Outlet Flow (1)

Oxygen Purity at the Outlet

90%

93%

95%

OGX 110

scfh

1.9

1.8

1.5

OGX 220

scfh

3.9

3.6

3

OGX 330

scfh

5.9

5.5

4.9

OGX 440

scfh

7.8

7.4

6.5

OGX 550

scfh

9.8

9.2

8.2

OGX 640

scfh

11.6

10.7

8.9

OGX 850

scfh

15.5

14.2

11.9

OGX 1070

scfh

19.3

17.8

14.9

Specifications

Standard

Optional

Design operating pressure range

65 to 145 psig / 4.5 to 10 barg

-

Design operating temperature range

41 to 122°F / 5 to 50°C

14 to 122°F / -10 to 50°C

Recommended operating temperature range

41 to 95°F / 5 to 35°C

-

Maximum inlet particulate

0.1 micron

-

Maximum inlet dew point

45°F PDP

-

Recommended inlet dew point

37.4°F PDP (2)

-

Maximum inlet oil content

0.01 ppm (3)

-

Supply voltage

100 - 240 VAC (50 or 60Hz)

-

(1) at 87 psig/6 barg inlet pressure and 68°F/20°C inlet temperature. For outlet flow at all other conditions, refer to the correction factors above or contact support

(2) including oil vapor

(3) -4°F PDP with low inlet temperature option