Stainless steel end caps for compatibility with autoclave sterilization with a guarantee for a minimum of 100 sterilization cycles at 248°F/120°C
Key Specs:
Flow Rate
15 to 1500 scfm
Connection
1⁄4” to 3” NPT
Filtration
0.01 micron
Product Documentation
- Brochures
- User Guide
F1 NMS - User Guide
F1 NMS - User Guide
- Filename
- F1-NMS-0015-1500-user-guide-manual-medical-sterile-filters.pdf
- Size
- 2 MB
- Format
Features
Each element is 100% integrity tested
Allows close coupling of filters to simplify installation and maintenance
Specifications of our models
Filter Model |
Element Part No. |
Inlet & Outlet |
Rated Flow (1) |
|
NPT |
scfm |
Nm3/h |
||
E0015 MS |
¼” |
15 |
25.5 |
|
E0035 MS |
¼” |
25 |
42.5 |
|
NMS 0035 |
E0035 MS |
⅜” |
35 |
59.5 |
E0050 MS |
½” |
50 |
85 |
|
E0085 MS |
½” |
70 |
119 |
|
E0085 MS |
¾” |
85 |
144 |
|
E0175 MS |
1” |
175 |
297 |
|
E0325 MS |
1 ¼” |
280 |
476 |
|
E0325 MS |
1 ½” |
325 |
550 |
|
E0450 MS |
1 ½” |
400 |
680 |
|
E0450 MS |
2” |
450 |
765 |
|
E0700 MS |
2” |
700 |
1190 |
|
E1000 MS |
2 ½” |
850 |
1445 |
|
E1000 MS |
3” |
1000 |
1700 |
|
E1250 MS |
3” |
1250 |
2125 |
|
E1500 MS |
3” |
1500 |
2550 |
Specifications |
NMS 0015 |
NMS 0025 to NMS 0050 |
NMS 0070 to NMS 1500 |
Design Operating Pressure Range |
0 to 232 psig / 0 to 16 bar |
0 to 232 psig / 0 to 16 bar |
0 to 232 psig/ 0 to 16 bar |
Condensate Drain (included) |
MDV 25 |
MDV 25 |
MDV 50 |
Differential Pressure Indicator / Gauge |
- |
NDP 0050 |
NDP 1500 |
Filter Housing Material |
Cast aluminum with e-Coat™ & powder top coat finish |
Element Performance |
|
DOP efficiency (3) |
>99.9999% |
Particle Removal |
0.01 micron |
Recommended Operating Temperature Range |
35 to 212°F / 2 to 100°C |
Design Operating Temperature Range |
35 to 248°F / 2 to 120°C |
Maximum Autoclave Temperature |
273°F / 134°C |
Pressure Drop - Clean |
1.5 psid |
Pressure Drop - Recommended Replacement |
6.0 psid |
End Cap Material |
Stainless Steel |
Flow Direction Through Element |
Outside to Inside |
Maximum Steam Sterilization Cycles |
100 |
Maximum Element Life |
6 months or 1000 hours |
(1) inlet and outlet connections are NPT threaded to ANSI B2.1
(2) at 100 psig/7 barg. For all other pressures, refer to the pressure correction factor table above
(3) as specified in HTM 02-01 medical gas pipeline systems
(4) applies to the element only
(5) technical specifications subject to change without notice. Direct inquiries to support or contact 704.897.2182