Fabricated from polished 304 or 316 stainless steel
Flow Rate
85 to 1150 scfm
Connection
½” to 3” NPT (F)
Filtration
1, 0.01 micron & AC
Product Documentation
- Brochures
Features
Interchangeable borosilicate microfiber element incorporate stainless steel support media and a positive double o-ring click-lock seal to ensure optimal filtration integrity
High tech manufacturing, food processing, beverage, oil and gas, offshore, marine, chemical and military
Specifications of our models
Filter Model |
Replacement Element Part No. |
Flange |
Rated Flow |
---|---|---|---|
NPT (F) |
scfm |
||
PF 0085 (grade) -N |
E 102 (grade) |
½” |
85 |
PF 0120 (grade) -N |
E 102 (grade) |
¾” |
120 |
PF 0170 (grade) -N |
E 105 (grade) |
1” |
170 |
PF 0460 (grade) -N |
E 110 (grade) |
2” |
460 |
PF 0850 (grade) -N |
E 120 (grade) |
2 ½” |
850 |
PF 1150 (grade) -N |
E 130 (grade) |
3” |
1150 |
Specifications |
Standard |
Optional |
|||||||
---|---|---|---|---|---|---|---|---|---|
Design operating pressure range |
0 to 232 psig |
- |
|||||||
Inlet & outlet connections |
NPT (F) |
tri-clamp sanitary |
|||||||
Drain & vent connections |
¼” BSPP |
- |
|||||||
Differential pressure indicator / hauge |
- |
on request |
|||||||
Filter housing material |
1.4301 auality |
1.4404 quality |
|||||||
304 stainless steel |
316L stainless steel |
Element Performance |
M1 |
M01 |
AC |
||||||
---|---|---|---|---|---|---|---|---|---|
Maximum particle size (ISO class) |
2 |
1 |
- |
||||||
Maximum oil content (ISO class) |
2 |
2 |
1 |
||||||
Particle removal (microns) |
1 |
0.01 |
- |
||||||
Max oil carry over at 68°F / 20°C (ppm or mg/m3) |
0.1 |
0.01 |
0.003 |
||||||
Oil removal efficiency at 68°F / 20°C |
>99.99% |
>99.999% |
- |
||||||
Recommended operating temperature range |
35 to 212°F |
35 to 212°F |
35 to 77°F |
||||||
Design operating temperature range |
35 to 248°F |
35 to 248°F |
35 to 122°F |
||||||
Pressure drop - clean |
1.0 psid |
1.5 psid |
1.85 psid |
||||||
Maximum element life |
12 months or 8000 hours |
6 months or 1000 hrs |
(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.