Fabricated from polished 304 or 316 stainless steel
85 to 1150 scfm
½” to 3” NPT(F)
1, 0.01 micron & AC
Interchangeable borosilicate microfiber element incorporate stainless steel support media and a positive double o-ring click-lock seal to ensure optimal filtration integrity
High tech manufacturing, food processing, beverage, oil and gas, offshore, marine, chemical and military
Filter Model |
Replacement Element Part No. |
Flange |
Rated Flow (1) |
|
NPT(F) |
scfm |
Nm3/h |
||
PF 0085 (grade) -N |
E 102 (grade) |
½” |
85 |
144 |
PF 0120 (grade) -N |
E 102 (grade) |
¾” |
120 |
204 |
PF 0170 (grade) -N |
E 105 (grade) |
1” |
170 |
289 |
PF 0460 (grade) -N |
E 110 (grade) |
2” |
460 |
782 |
PF 0850 (grade) -N |
E 120 (grade) |
2 ½” |
850 |
1444 |
bPF 1150 (grade) -N |
E 130 (grade) |
3” |
1150 |
1954 |
Specifications |
Standard |
Optional |
|||||||
Design Operating Pressure Range |
0 to 232 psig / 0 to 16 bar |
- |
|||||||
Inlet & Outlet Connections |
NPT(F) |
tri-clamp sanitary |
|||||||
Drain & Vent Connections |
1/4” BSPP |
- |
|||||||
Differential Pressure Indicator / Gauge |
- |
on request |
|||||||
Filter Housing Material |
1.4301 quality |
1.4404 quality |
|||||||
304 stainless steel |
316L stainless steel |
Element Performance |
M1 |
M01 |
AC |
||||||
Maximum Particle Size (ISO Class) (3) |
2 |
1 |
- |
||||||
Maximum Oil Content (ISO Class) (3) |
2 |
2 |
1 |
||||||
Particle Removal (microns) |
1 |
0.01 |
- |
||||||
Max Oil Carry Over at 68°F / 20°C (ppm or mg/m3) |
0.1 |
0.01 |
0.003 |
||||||
Oil Removal Efficiency at 68°F / 20°C |
>99.99% |
>99.999% |
- |
||||||
Recommended Operating Temp Range |
35 to 212°F / 2 to 100°C |
35 to 212°F / 2 to 100°C |
35 to 77°F / 2 to 25°C |
||||||
Design Operating Temperature Range |
35 to 248°F / 2 to 120°C |
35 to 248°F / 2 to 120°C |
35 to 122°F / 2 to 50°C |
||||||
Pressure Drop - Clean |
1.0 psid |
1.5 psid |
1.85 psid |
||||||
Maximum Element Life |
12 months or 8000 hours |
6 months or 1000 hrs |
(1) at 100 psig. For all other pressures, refer to the pressure correction factors above
(2) +/- 0.118”
(3) per ISO 8573-1:2010
(4) install with air flow from inside to outside for coalescing and from outside to inside for dry dust filtration