A nano legacy model, the R2 RTC refrigerated dryer

Legacy Equipment

RTC High-Inlet Temperature Cycling Refrigerated Dryers

The RTC high-inlet temperature refrigerated dryer range has been superseded by the HTR high-inlet temperature direct expansion refrigerated dryer range. Replacement parts and support materials for the legacy RTC products remain available and can be found below.

Product Documentation

nano-purification solutions product brochure with equipment details

EN-R2-RTC-brochure-high-temperature-thermal-mass-cycling-dryers

nano-purification solutions product brochure with equipment details
Filename
EN-R2-RTC-brochure-high-temperature-thermal-mass-cycling-dryers.pdf
Size
268 KB
Format
pdf
View
ISO compressed air quality standards brochure

ISO Compressed Air Quality Standards

ISO compressed air quality standards brochure
Filename
EN-ISO-brochure-compressed-air-quality-standards.pdf
Size
7 MB
Format
pdf
View
general arrangement drawing nano equipment

RTC 0035-0125 - General Arrangement (GA) Drawing

general arrangement drawing nano equipment
Filename
R2-RTC-0035-0125-ga-general-arrangement-drawing-without-filter.pdf
Size
363 KB
Format
pdf
View
RTC 0010 to 0075 High-Inlet Temperature Cycling Refrigerated Dryers - R134a

RTC 0010 to 0075 High-Inlet Temperature Cycling Refrigerated Dryers - R134a

Material Safety Data Sheet

Filename
R1-NXC-msds-cycling-refrigerated-dryers-R134a.pdf
Size
194 KB
Format
pdf
View
RTC 0125 High-Inlet Temperature Cycling Refrigerated Dryers - R407c

RTC 0125 High-Inlet Temperature Cycling Refrigerated Dryers - R407c

Material Safety Data Sheet

Filename
R1-NXC-msds-cycling-refrigerated-dryers-R407C.pdf
Size
225 KB
Format
pdf
View
nano equipment user guide

R2-RTC-0010-0125-user-guide-manual-high-temperature-cycling-refrigerated-dryer

nano equipment user guide
Filename
R2-RTC-0010-0125-user-guide-manual-high-temperature-cycling-refrigerated-dryer.pdf
Size
2 MB
Format
pdf
View

Technical Data by Model

Dryer Model

Prefilter as Standard

Inlet & Outlet

 Rated Flow at 125 psig

Absorbed Power

Power Supply (V/Ph/60Hz)

NPT

scfm

kW

115/1

230/1

RTC 0010-F

GF 0050 M1

½”

10

0.23

 

RTC 0015-F

GF 0085 M1

¾”

15

0.24

 

RTC 0025-F

GF 0085 M1

¾”

25

0.25

 

RTC 0035-F

GF 0105 M1

1”

35

0.47

 

RTC 0050-F

GF 0105 M1

1”

50

0.49

 

RTC 0075-F

GF 0325 M1

1 ½”

75

0.97

 

RTC 0125-F

GF 0450 M1

2”

125

1.41

 


Specifications

Design operating pressure range

0 to 232 psig 

Maximum inlet temperature

158°F 

Maximum ambient temperature 

110°F to 122°F depending on refrigerant

Prefilter (included) 

M1 (1 micron)

Condensate drain (included) 

automatic timed solenoid

(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change

Let's Connect

Get world-class experience with nano today.

Abstract polygonal space background blue with connection lines and dots.