Product Documentation
- Brochures
 - General Arrangement Drawings
 - Installation Diagram
 - Material Safety Data Sheets
 - User Guides
 
Specifications of these models
Generator Model  | 
Rated Outlet Flow at 100 psig  | 
Nitrogen Purity at the Outlet (Maximum Oxygen Content)  | 
|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
99.999%  | 
99.995%  | 
99.99%  | 
99.75%  | 
99.95%  | 
99.9%  | 
99.5%  | 
99%  | 
98%  | 
97%  | 
96%  | 
95%  | 
||
GEN2 1110  | 
scfh  | 
49  | 
71  | 
81  | 
95  | 
109  | 
127  | 
184  | 
205  | 
258  | 
293  | 
335  | 
364  | 
GEN2 2110  | 
scfh  | 
99  | 
141  | 
162  | 
191  | 
219  | 
254  | 
367  | 
410  | 
516  | 
586  | 
671  | 
727  | 
GEN2 3110  | 
scfh  | 
148  | 
212  | 
244  | 
286  | 
328  | 
381  | 
551  | 
614  | 
773  | 
879  | 
1006  | 
1091  | 
GEN2 2130  | 
scfh  | 
180  | 
254  | 
297  | 
353  | 
403  | 
466  | 
667  | 
742  | 
932  | 
1070  | 
1218  | 
1324  | 
GEN2 3130  | 
scfh  | 
270  | 
381  | 
445  | 
529  | 
604  | 
699  | 
1001  | 
1112  | 
1398  | 
1605  | 
1828  | 
1986  | 
GEN2 4130  | 
scfh  | 
360  | 
509  | 
593  | 
706  | 
805  | 
932  | 
1335  | 
1483  | 
1865  | 
2140  | 
2437  | 
2649  | 
GEN2 6130  | 
scfh  | 
540  | 
763  | 
890  | 
1058  | 
1208  | 
1395  | 
2002  | 
2225  | 
2797  | 
3210  | 
3655  | 
3973  | 
GEN2 8130  | 
scfh  | 
720  | 
1017  | 
1187  | 
1411  | 
1610  | 
1865  | 
2670  | 
2966  | 
3729  | 
4280  | 
4873  | 
5297  | 
GEN2 110130  | 
scfh  | 
828  | 
1170  | 
1365  | 
1623  | 
1852  | 
2144  | 
3070  | 
3411  | 
4289  | 
4922  | 
5604  | 
6092  | 
GEN2 12130  | 
scfh  | 
962  | 
1358  | 
1584  | 
1884  | 
2150  | 
2489  | 
3564  | 
3960  | 
4979  | 
5714  | 
6506  | 
7072  | 
Specifications  | 
|
|---|---|
Design operating pressure range  | 
87 - 175 psig  | 
Design operating temperature range  | 
41-122°F  | 
Maximum inlet particulate  | 
0.1 micron  | 
Maximum inlet dew point  | 
80°F PDP  | 
Maximum inlet oil content  | 
0.01 ppm  | 
Maximum outlet dew point  | 
-40°F  | 
Supply voltage  | 
100 - 240 VAC (50 or 60Hz) or 24VDC  | 
(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.