A mid-pressure filter with its internal filtration element

Compressed Air & Gas Filters

N50A Mid-Pressure Aluminum Filters

The  N50A mid-pressure aluminum filter range has been superseded by the G50N mid-pressure aluminum filter range. Replacement elements, parts and support materials for the legacy N50A products remain available.

Product Documentation

nano-purification solutions product brochure with equipment details

N50A Mid-Pressure Aluminum Filters

Product Brochure

Filename
EN-F3-N50A-brochure-mid-pressure-aluminum-filters.pdf
Size
625 KB
Format
pdf
View
ISO compressed air quality standards brochure

ISO Compressed Air Quality Standards Brochure

Support Brochure

Filename
EN-ISO-brochure-compressed-air-quality-standards.pdf
Size
7 MB
Format
pdf
View
The general arrangement drawing for the F3 N50A mid pressure aluminum filter, model 0147

N50A 0147 Mid-Pressure Aluminum Filters

General Arrangement Drawing

Filename
F3-N50A-0147-ga-general-arrangement-drawing-mid-pressure-aluminum-filter.pdf
Size
203 KB
Format
pdf
View

Technical Data by Model

Filter Model

Replacement Element

Inlet & Outlet

Rated Flow at 725 psig

Part No.

NPT

scfm

N50A 0094 (grade)

E50HP 0094 (grade)

¼”

94

N50A 0147 (grade)

E50HP 0147 (grade)

⅜”

147

N50A 0265 (grade)

E50HP 0265 (grade)

½”

265

N50A 0324 (grade)

E50HP 0324 (grade)

¾”

324

N50A 0492 (grade)

E50HP 0492 (grade)

1”

492

N50A 0736 (grade)

E50HP 0736 (grade)

1½”

736

N50A 1015 (grade)

E50HP 1132 (grade)

1½”

1015

N50A 1132 (grade)

E50HP 1132 (grade)

2”

1132

N50A 1882 (grade)

E50HP 1882 (grade)

2”

1882


Specifications

Design operating pressure range 

0 to 725 psig 

Condensate drain (included)

manual ball valve

Filter housing material

machined & die-cast aluminum


Element Performance

WS

M25

M5

M1

M01

AC

Particle removal 

-

25 micron

5 micron

1 micron

0.01 micron

-

Max oil carryover at 68°F 

25 ppm

10 ppm

5 ppm

0.1 ppm

0.01 ppm

0.003 ppm

Recommended operating temp range 

35 to 212°F

35 to 212°F

35 to 212°F

35 to 212°F

35 to 212°F

35 to 77°F

Design operating temperature range

35 to 248°F

35 to 248°F

35 to 248°F

35 to 248°F

35 to 248°F

35 to 248°F