Product Documentation
- Brochures
- GA Drawing
- User Guides
Specifications of these models
Filter Model |
Replacement Element |
Inlet & Outlet |
Rated Flow at 100 psig |
---|---|---|---|
NPT |
scfm |
||
NF - Coalescing, Particulate, or Activated Carbon |
|||
E 0008 (grade) |
¼” |
8 |
|
E 0015 (grade) |
¼” |
15 |
|
E 0025 (grade) |
¼” |
25 |
|
E 0030 (grade) |
½” |
30 |
|
E 0035 (grade) |
⅜” |
35 |
|
E 0050 (grade) |
½” |
50 |
|
E 0090 (grade) |
½” |
70 |
|
E 0090 (grade) |
¾” |
85 |
|
E 0090 (grade) |
1” |
90 |
|
E 0135 (grade) |
¾” |
125 |
|
E 0135 (grade) |
1” |
135 |
|
E 0175 (grade) |
1” |
175 |
|
E 0325 (grade) |
1 ¼” |
280 |
|
E 0325 (grade) |
1 ½” |
290 |
|
E 0325 (grade) |
1 ½” |
325 |
|
E 0450 (grade) |
1 ½” |
400 |
|
E 0450 (grade) |
2” |
450 |
|
E 0700 (grade) |
2” |
700 |
|
E 1000 (grade) |
2 ½” |
850 |
|
E 1000 (grade) |
3” |
1000 |
|
E 1250 (grade) |
3” |
1250 |
|
E 1500 (grade) |
3” |
1500 |
|
NFD (Duplex) - 0.01 Micron Coalescing & Activated Carbon |
|||
NFD 25 |
E 0025 M01DAC |
¼” |
25 |
NFD 35 |
E 0035 M01DAC |
⅜” |
35 |
NFD 50 |
E 0050 M01DAC |
½” |
50 |
NFD 70 |
E 0085 M01DAC |
½” |
70 |
NFD 85 |
E 0085 M01DAC |
¾” |
85 |
NFD 125 |
E 0135 M01DAC |
¾” |
125 |
NFD 135 |
E 0135 M01DAC |
1” |
135 |
NFD 175 |
E 0175 M01DAC |
1” |
175 |
Specifications |
NF 0008 to NF 0015 |
NF 0025 to NF 0050 |
NF 0070 to NF 1500 |
NFD 25 to NFD 50 |
NFD 70 to NFD 175 |
---|---|---|---|---|---|
Design operating pressure range |
0 to 232 psig | 0 to 232 psig | 22 to 232 | 0 to 232 psig | 22 to 232 |
Automatic float drain | NDK 0050 |
NDK 0050 |
NDK 1500 |
NDK 0050 |
NDK 1500 |
Differential pressure indicator / gauge |
- |
NDP 0050 |
NDP 1500 |
- |
- |
Specifications |
M25 |
M5 |
M1 |
M01 |
AC |
DAC |
---|---|---|---|---|---|---|
Maximum particle size (ISO class) |
- |
3 |
2 |
1 |
- |
1 |
Maximum oil content (ISO class) |
- |
4 |
2 |
1 |
1 |
1 |
Particle removal |
25 micron |
5 micron |
1 micron |
0.01 micron |
- |
0.01 micron |
Max oil carry over at 68°F |
10 ppm |
5 ppm |
0.1 ppm |
0.01 ppm |
0.003 ppm |
0.003 ppm |
Recommended operating temp range |
35 to 176°F |
35 to 176°F |
35 to 176°F |
35 to 176°F |
35 to 77°F |
35 to 77°F |
Design operating temperature range |
35 to 176°F | 35 to 176°F | 35 to 176°F | 35 to 176°F | 35 to 122°F | 25 to 122°F |
(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.