Dryer Model |
Inlet & Outlet (1) |
Rated Flow (2) |
Pressure Drop |
Compressor(s) |
Absorbed Power (3) |
||||
NPT(M) / Flg |
scfm |
Nm3/h |
psi / bar |
qty |
hp |
Type |
kW |
amps |
|
3” |
1250 |
2124 |
1.6 / 0.1 |
1 |
8 |
scroll |
10.4 |
16.4 |
|
3” |
1500 |
2548 |
2.0 / 0.1 |
1 |
9 |
scroll |
11.8 |
17.5 |
|
3” |
1500 |
2548 |
2.0 / 0.1 |
1 |
7.5 |
semi-hermetic |
7.5 |
14.1 |
|
4” |
1750 |
2973 |
2.8 / 0.2 |
1 |
10 |
scroll |
13.9 |
17.8 |
|
4” |
1750 |
2973 |
2.8 / 0.2 |
1 |
7.5 |
semi-hermetic |
7.5 |
14.1 |
|
4” |
2000 |
3398 |
3.5 / 0.2 |
2 |
12 |
scroll |
15.1 |
18.6 |
|
6” |
2250 |
3823 |
4.4 / 0.3 |
1 |
10 |
semi-hermetic |
10.7 |
20 |
|
6” |
2500 |
4247 |
1.5 / 0.1 |
2 |
16 |
scroll |
15.1 |
18.6 |
|
6” |
2500 |
4247 |
1.5 / 0.1 |
1 |
10 |
semi-hermetic |
10.7 |
20 |
|
6” |
3200 |
5437 |
2.5 / 0.2 |
2 |
20 |
scroll |
27.7 |
35.6 |
|
8” |
3200 |
5437 |
2.5 / 0.2 |
1 |
15 |
semi-hermetic |
15.1 |
29 |
|
8” |
4000 |
6796 |
2.8 / 0.2 |
1 |
28 |
semi-hermetic |
30.5 |
45.8 |
|
8” |
4000 |
6796 |
2.8 / 0.2 |
1 |
20 |
semi-hermetic |
20.1 |
53.6 |
|
8” |
5000 |
8495 |
4.2 / 0.3 |
1 |
35 |
semi-hermetic |
38.5 |
57.5 |
|
8” |
5000 |
8495 |
4.2 / 0.3 |
1 |
30 |
semi-hermetic |
38.3 |
48.1 |
|
8” |
6250 |
10618 |
4.5 / 0.3 |
1 |
40 |
semi-hermetic |
44.4 |
65.2 |
|
8” |
6250 |
10618 |
4.5 / 0.3 |
1 |
35 |
semi-hermetic |
42.3 |
53.2 |
|
8” |
7500 |
12742 |
6.5 / 0.4 |
1 |
40 |
semi-hermetic |
37.5 |
79.3 |
Specifications |
|
Heat exchanger type |
shell and finned tube |
Design operating pressure |
0 to 150 psig / 0 to 10.3 bar |
Design /maximum inlet air temperature range |
100°F / 120°F 38°C / 49°C |
Design /maximum ambient temperature range |
100°F / 110°F 38°C / 43°C |
Condenser cooling options |
air-cooled (-A) or water-cooled (-W) |
Refrigerant type |
refrigerant type R404A or R407C (dependent on model) |
Control panel enclosure |
NEMA 1 (4) |
Power supply requirements |
460V/3Ph/60Hz |
(1) -1250 and -1500 are NPT(M); -1750 and above are 150# ANSI Flg connections
(2) in compliance with ADF 100 specifications for compressed air dryers; inlet temperature: 100°F/38°C, ambient temperature: 100°F/38°C, inlet pressure:
100 psig/6.9 bar, pressure dew point: 33°F to 39°F /1 to 4°C . For all other conditions refer to the correction factors above or contact support
(3) nominal absorbed power at rated operating conditions using 460/3/60 power supply (as applicable). For absorbed power at other voltages or conditions, contact support
(6) for larger models or 575V, contact [email protected]
(7) remote condenser standard on models STR 4000-A-RC - STR 7500-A-AC
(8) lowest standard ambient condition is 50°F/10°C. Below 50°F/10°C, contact factory
(9) technical specifications subject to change without notice. Direct inquiries to support or contact 704.897.2182