Blog 

Legacy Equipment

STR Open-Frame Process Refrigerated Dryers

The unique nano direct expansion, dual action, shell and finned tube heat exchangers provide very low pressure drop and superior dew point performance because of the copper tube aluminum-finned design. This design incorporates both primary and secondary heat transfer surface areas, which eliminates the need for a mechanical separator. All of this translates into one of the most efficient and cost-saving products on the market, with one of the lowest pressure drops in the industry.

nano-purification solutions product brochure with equipment details

R3 STR - Brochure

Filename
EN-R3-STR-brochure-open-frame-refrigerated-process-dryers.pdf
Size
3 MB
Format
application/pdf
View
nano equipment user guide

R3 STR - User Guide

Filename
R3-STR-user-guide-open-frame-process-refrigerated-dryers.pdf
Size
2 MB
Format
application/pdf
View

Specifications of these models

Dryer Model

Inlet & Outlet (1)

Rated Flow (2)

Pressure Drop

 

Compressor(s)

Absorbed Power (3)

NPT(M) / Flg

scfm

Nm3/h

psi / bar

qty

hp

Type

kW

amps

STR 1250-A

3”

1250

2124

1.6 / 0.1

1

8

scroll

10.4

16.4

STR 1500-A

3”

1500

2548

2.0 / 0.1

1

9

scroll

11.8

17.5

STR 1500-W

3”

1500

2548

2.0 / 0.1

1

7.5

semi-hermetic

7.5

14.1

STR 1750-A

4”

1750

2973

2.8 / 0.2

1

10

scroll

13.9

17.8

STR 1750-W

4”

1750

2973

2.8 / 0.2

1

7.5

semi-hermetic

7.5

14.1

STR 2000-A

4”

2000

3398

3.5 / 0.2

2

12

scroll

15.1

18.6

STR 2000-W

6”

2250

3823

4.4 / 0.3

1

10

semi-hermetic

10.7

20

STR 2500-A

6”

2500

4247

1.5 / 0.1

2

16

scroll

15.1

18.6

STR 2500-W

6”

2500

4247

1.5 / 0.1

1

10

semi-hermetic

10.7

20

STR 3200-A

6”

3200

5437

2.5 / 0.2

2

20

scroll

27.7

35.6

STR 3200-W

8”

3200

5437

2.5 / 0.2

1

15

semi-hermetic

15.1

29

STR 4000-A-RC

8”

4000

6796

2.8 / 0.2

1

28

semi-hermetic

30.5

45.8

STR 4000-W

8”

4000

6796

2.8 / 0.2

1

20

semi-hermetic

20.1

53.6

STR 5000-A-RC

8”

5000

8495

4.2 / 0.3

1

35

semi-hermetic

38.5

57.5

STR 5000-W

8”

5000

8495

4.2 / 0.3

1

30

semi-hermetic

38.3

48.1

STR 6250-A-RC

8”

6250

10618

4.5 / 0.3

1

40

semi-hermetic

44.4

65.2

STR 6250-W

8”

6250

10618

4.5 / 0.3

1

35

semi-hermetic

42.3

53.2

STR 7500-W

8”

7500

12742

6.5 / 0.4

1

40

semi-hermetic

37.5

79.3

Specifications

Heat exchanger type

shell and finned tube

Design operating pressure

0 to 150 psig / 0 to 10.3 bar

Design /maximum inlet air temperature range 

100°F / 120°F

38°C / 49°C

Design /maximum ambient temperature range 

100°F / 110°F

38°C / 43°C

Condenser cooling options

air-cooled (-A) or water-cooled (-W)

Refrigerant type

refrigerant type R404A or R407C (dependent on model)

Control panel enclosure

NEMA 1 (4)

Power supply requirements

460V/3Ph/60Hz

(1) -1250 and -1500 are NPT(M); -1750 and above are 150# ANSI Flg connections
(2) in compliance with ADF 100 specifications for compressed air dryers; inlet temperature: 100°F/38°C, ambient temperature: 100°F/38°C, inlet pressure: 100 psig/6.9 bar, pressure dew point: 33°F to 39°F /1 to 4°C . For all other conditions refer to the correction factors above or contact support
(3) nominal absorbed power at rated operating conditions using 460/3/60 power supply (as applicable). For absorbed power at other voltages or conditions, contact support
(6) for larger models or 575V, contact [email protected]
(7) remote condenser standard on models STR 4000-A-RC - STR 7500-A-AC
(8) lowest standard ambient condition is 50°F/10°C. Below 50°F/10°C, contact factory
(9) technical specifications subject to change without notice. Direct inquiries to support or contact 704.897.2182

Let's Connect

Get world-class experience with nano today.

Worker