Includes air-cooled air driven aftercooler, high efficiency water separator, pre-filtration with automatic drains, high performance twin tower heatless desiccant dryer and high efficiency after filters
Key Specs:
Flow Rate
1300 to 3800 scfm
Connection
3” NPT(F) to 6” Flg
Air Quality
ISO 8573.1:2010 Class 1.2.1 or 1.1.2
Product Documentation
- Brochures
- Material Safety Data Sheets
Features
Operated by a robust and reliable PLC system housed in a NEMA4X control panel
Pneumatically actuated high-performance butterfly valves for the highest reliability
Specifications of our models
Dryer Model |
Filtration |
Inlet & Outlet |
Rated Flow at 100 psig |
||
---|---|---|---|---|---|
Water |
Prefilter |
After Filter |
NPT (F)/ Flg |
scfm |
|
HLA 1300-F2-RENTAL |
NF 1500 WS |
NF 1500 M01 |
NF 1500 M1 |
3” |
1300 |
HLA 1500-F2-RENTAL |
NF 1500 WS |
NF 1500 M01 |
NF 1500 M1 |
3” |
1500 |
HLA 3800-F2-RENTAL |
AFE4000WS |
NFZ 3000 M01 |
NFZ 3000 M1 |
6” Flg |
3800 |
Specifications |
Standard |
Optional |
---|---|---|
Maximum particle size (ISO class) |
class 2 (1 micron) |
class 1 (0.01 micron) |
Maximum water content (ISO class) |
class 2 (-40°F pdp) |
class 1 (-94°F pdp) |
Minimum/ design /maximum operating pressure range |
70 psig / 100 psig / 150 psig |
- |
Minimum / design/ maximum ambient temperature |
38°F / 100°F / 120°F |
- |
Minimum / design / maximum inlet temperature |
38°F / 100°F/ 120°F |
- |
Power supply requirements |
115V/1Ph/60Hz |
230V/1Ph/60Hz & 12 VDC |
(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.