| Dryer Models | Recommended Pre & After Filtration | Inlet & Outlet | Rated Flow at 100 psig | Heater | |
|---|---|---|---|---|---|
| Pre Filter | After Filter | NPT (F) / FLG | scfm | kW | |
| GF 0105 M01 | NHT 0150 M1 | 1" | 100 | 1.5 | |
| GF 0325 M01 | NHT 0300 M1 | 1 ½" | 175 | 3 | |
| GF 0325 M01 | NHT 0300 M1 | 1 ½" | 250 | 3 | |
| GF 0450 M01 | NHT 0450 M1 | 2" | 350 | 6 | |
| GF 0700 M01 | NHT 0650 M1 | 2" | 500 | 6 | |
| GF 0700 M01 | NHT 1000 M1 | 2" | 700 | 9 | |
| GF 0850 M01 | NHT 1000 M1 | 2" | 850 | 9 | |
| GF 1250 M01 | NHT 1000 M1 | 3" | 1000 | 12.5 | |
| GF 1500 M01 | NHT 1600 M1 | 3" | 1350 | 12.5 | |
| NFZ 2500 M01 | NFZ 2500 M1HT | 3" | 1700 | 18 | |
| NFZ 2500 M01 | NFZ 2500 M1HT | 4" Flg | 2100 | 25 | |
| NFZ 2500 M01 | NFZ 2500 M1HT | 4" Flg | 2400 | 25 | |
| NFZ 3500 M01 | NFZ 3500 M1HT | 4" Flg | 3100 | 30 | |
| NFZ 4000 M01 | NFZ 4000 M1HT | 6" Flg | 3800 | 40 | |
| NFZ 5000 M01 | NHT 5000 M1HT | 6" Flg | 4300 | 50 | |
| NFZ 5000 M01 | NHT 5000 M1HT | 6" Flg | 5000 | 50 | |
| Specifications | Standard | Optional | 
|---|---|---|
| Maximum water content (ISO class) | class 2 (1 micron) | class 1 (0.01 micron) | 
| Maximum water content (ISO class) | class 2 (-40°F PDP) | - | 
| Minimum/ design /maximum operating pressure range | 80 psig / 100 psig / 150 psig | 58 to 250 psig | 
| Minimum / design/ maximum ambient temperature | 38°F / 100°F / 120°F | - | 
| Minimum / design / maximum inlet temperature | 38°F / 100°F/ 120°F | - | 
| Power supply requirements | 460VAC/60Hz | 575V/60Hz or 380 VAC/50Hz | 
(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.