Plug-and-play design is fully packaged into a simple compact design, allowing these models to fit into the smallest spaces.
Key Specs:
Flow Rate
10 to 4200 scfm
Connection
½” NPT (M) to 6” Flg
Air Quality
ISO 8573.1:2010 Class 5
Product Documentation
- Brochures
- Electrical Diagrams
- Flow Diagrams
- General Arrangement Drawings
- Material Safety Data Sheets
- Spare Parts Lists
- User Guides
- Worksheets
Features
Powder-coated steel panels for optimum corrosion resistance.
Pre- and after filter packages available to provide additional energy savings and improved air quality.
Specifications of our models
Dryer Model |
Inlet & |
Rated Flow |
Absorbed Power |
Power Supply (V/Ph/60Hz) | Refrigerant | |||
---|---|---|---|---|---|---|---|---|
NPT/FLG |
scfm |
kW |
115/1 |
230/1 |
460/3 |
545/3 |
||
DXR 0010 NA |
½” (M) |
10 |
0.2 |
• |
R513A |
|||
DXR 0015 NA |
½” (M) |
15 |
0.2 |
• |
R513A |
|||
DXR 0020 NA |
½” (M) |
20 |
0.2 |
• |
R513A |
|||
DXR 0030 NA |
½” (M) |
30 |
0.3 |
• |
R513A |
|||
DXR 0050 NA |
½” (M) |
50 |
0.9 |
• |
R513A |
|||
DXR 0065 NA |
¾” (M) |
65 |
0.9 |
• |
R513A |
|||
DXR 0085 NA |
1" (F) |
85 |
1.0 |
• |
R410A |
|||
DXR 0105 NA |
1" (F) |
105 |
1.0 |
• |
R410A |
|||
DXR 0125 NA |
1” (F) |
125 |
1.0 |
• |
R410A |
|||
DXR 0150 NA |
1” (F) |
150 |
1.5 |
• |
R410A |
|||
DXR 0185 NA |
1½” (F) |
185 |
1.6 |
• |
R410A |
|||
DXR 0230 NA |
1½” (F) |
230 |
2.0 |
• |
R410A |
|||
DXR 0250 NA |
1½” (F) |
250 |
2.4 |
• |
R410A |
|||
DXR 0325 NA |
2” (F) |
325 |
2.3 |
• |
R410A |
|||
DXR 0400 NA |
2” (F) |
400 |
3.2 |
• |
R410A |
|||
DXR 0500 NA |
2 ½" (F) |
500 |
3.2 |
• |
R410A |
|||
DXR 0600 NA |
2 ½” (F) |
600 |
4.2 |
• |
R410A |
|||
DXR 0850 NA |
3" (M) |
850 |
5.8 |
• |
• |
R410A |
||
DXR 1050 NA |
3" (M) |
1050 |
6.0 |
• |
• |
R410A |
||
DXR 1250 NA |
3" (M) |
1250 |
6.7 |
• |
• |
R410A |
||
DXR 1600 NA |
4” Flg |
1600 |
7.8 |
• |
• |
R410A |
||
DXR 1800 NA |
4” Flg |
1800 |
9.4 |
• |
• |
R410A |
||
DXR 2200 NA |
4” Flg |
2200 |
9.5 |
• |
• |
R410A |
||
DXR 2400 NA |
4” Flg |
2400 |
9.7 |
• |
• |
R410A |
||
DXR 3000 NA |
6” Flg |
3000 |
11.4 |
• |
• |
R410A |
||
DXR 3500 NA |
6” Flg |
3500 |
12.8 |
• |
• |
R410A |
||
DXR 4200 NA |
6” Flg |
4200 |
17.1 |
• |
• |
R410A |
Specifications |
DXR 0010 to DXR 0030 |
DXR 0050 to DXR 0250 |
DXR 0325 to DXR 4200 |
---|---|---|---|
Design operating pressure range |
0 to 232 psig |
60 to 203 psig |
60 to 203 psig |
Maximum inlet air temperature |
131°F |
131°F |
140°F |
Maximum ambient temperature |
41°F - 114.8°F |
41°F - 114.8°F |
41°F - 114.8°F |
(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.