nano NDC CO2 Removal Adsorption Dryer for On-Site Purge Gas Generation

Compressed Air Dryers

On-demand CO2‑free purge gas—no cylinders required

Replace traditional purge gas cylinders with the nano range of CO2‑free air dryers, engineered to deliver a continuous, reliable supply of clean, dry, CO2‑free air for critical lab applications.

Connect nano's CO2-free air dryer to your existing compressed air line to generate purge gas in-house, cut running costs, eliminate changeouts, and avoid interruptions that can lead to downtime, recalibration, and safety concerns.

Ideal for: FTIR purge, TOC purge, NMR, GC flame gas, and laser purging

Switch to a nano NDC range of CO2-free air dryer today for a simpler, safer, more cost-effective workflow.

Key Specs

Flow Rate

5.3 to 424 ft3/hr

Connection

⅜” PTC to 1” NPT (F)

Air Quality

CO2 levels of less than 1 ppm

Product Documentation

nano NDC CO2 Removal Adsorption Dryer Brochure for Canada

NDC CO2 Removal Dryers

Product Brochure

Filename
en-ca-ndc-co2-removal-dryer-brochure-000.pdf
Size
1 MB
Format
pdf
View
ISO compressed air quality standards brochure

ISO Compressed Air Quality Standards

Product Brochure

Filename
EN-ISO-brochure-compressed-air-quality-standards.pdf
Size
7 MB
Format
pdf
View
Declaration of Conformity - EC Council Directive

NDC 0015 to 0140 Declaration of Conformity

Certificate

Filename
EC-Declaration-of-Conformity-2014-68-EU-COC-NDL-0010-0020-NDC-015-140.pdf
Size
123 KB
Format
pdf
View
Declaration of Conformity - EC Council Directive

NDC 0300 to 0600 Declaration of Conformity

Certificate

Filename
EC-Declaration-of-Conformity-2014-68-EU-NDL-030-050-NBA-030-050-NDC-300-600.pdf
Size
124 KB
Format
pdf
View
Declaration of Conformity - EC Council Directive

NDC 0900 to 1200 Declaration of Conformity

Certificate

Filename
EC-Declaration-of-Conformity-2014-68-EU-NDL-060-130-NDC-900-1200-NBA-060-120.pdf
Size
124 KB
Format
pdf
View
equipment electrical wiring diagram and electrical schematics

NDC 015 to 1200 CO2 Removal Dryers

Electrical Diagram

Filename
L1-CO2-electrical-wiring-schematics-CO2-removal-dryer.pdf
Size
88 KB
Format
pdf
View
ga general arrangement drawing

NDC 015 to 600 CO2 Removal Dryers

General Arrangement Drawing

Filename
L1-NDC-015-600-ga-general-arrangement-drawing-CO2-adsorption-dryer-removal.PDF
Size
363 KB
Format
pdf
View
ga general arrangement drawing

NDC 900 to 1200 CO2 Removal Dryers

General Arrangement Drawing

Filename
L1-NDC-900-1200-ga-general-arrangement-drawing-CO2-adsorption-dryer-removal.PDF
Size
709 KB
Format
pdf
View

NDC CO2 Removal Dryers - Sylobead MS 514

Material Safety Data Sheet

Filename
EN-L1-NDC-MSDS-oil-vapor-removal-Sylobead-MS-514-Rev 6.9.pdf
Size
437 KB
Format
pdf
View

NDC CO2 Removal Dryers

service intervals

Filename
EN-US-L1-NDC-parts-guide-co2-removal-dryer-ver-000.pdf
Size
546 KB
Format
pdf
View

NDC CO2 Removal Dryers

spare parts guide

Filename
EN-US-L1-NDC-parts-guide-co2-removal-dryer-ver-000.pdf
Size
546 KB
Format
pdf
View
NDC Lab Gas CO2 Removal Dryers User Guide

NDC 015 to 1200 Lab Gas CO2 Removal Dryers

User Guide

Filename
L1-NDC-015-1200-user-guide-co2-removal-dryers.pdf
Size
3 MB
Format
pdf
View

Key Benefits

These models were developed for laboratories, so these units require no bench space, can be wall mounted, and ensure quiet operation with a novel exhaust silencer.

Each model requires less than 15 minutes for maintenance due to unique factory built-in filtration and adsorption cartridges.

PLC Controller with clear text display as standard.


Model Selection & Service Kits

CO2 Removal

Dryer Model

Standard
Prefiltration

Optional
Prefiltration

Service Kit

Inlet & Outlet 

Inlet Air Flow at 100 psig

Outlet Gas Flow 

Part No. Part No.

Part No.

NPT (f)

ft3/h

ft3/hr

NDC 015 GF

GF N0025 M01

GFN 0025 AC

NDK011GF

3/8” PTC

5.3

3.2

NDC 050 GF

GF N0025 M01

GFN 0025 AC

NDK011GF

3/8” PTC

17.6

10.6

NDC 140 GF

GF N0025 M01

GFN 0025 AC

NDK021GF

3/8” PTC

53

32

NDC 300 GF

GF N0025 M01

GFN 0025 AC

NDK031GF

3/8” PTC

106

64

NDC 600 GF

GFN 0050 M01

GFN 0050 AC

NDK051GF

½” PTC

212

127

NDC 900 GF

GFN 0105 M01

GFN 0105 AC

NDK061GF

1”

318

191

NDC 1200 GF

GFN 0105 M01

GFN 0105 AC

NDK071GF

1”

424

254

Outlet Gas Quality

Standard

Optional

Maximum CO2 content

1 ppm

-

Maximum pressure dew point

-94°F 

-

Maximum particulate size

1 micron

0.01 micron

Maximum oil content

-

0.003 ppm

Specifications

NDC 015 GF to NDC 300 GF

NDC 600 GF to NDC 1200 GF

Design operating pressure range

58 to 145 psig 

58 to 174 psig 

Recommended operating temperature range

59 to 86°F 

Power supply requirements

50 or 60 Hz, 100 to 240 VAC

Maximum noise level (during depressurization)

60 dBa

Manufacturing quality standards

ISO 9001.2015 & CE

Warranty

1 year

(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.      

Related Products

Low‑Capacity Nitrogen Generators for Small‑Scale Applications

nano’s GEN2 MINI delivers reliable, high‑purity nitrogen in a compact, low‑capacity design ideal for small‑scale applications.

nano GEN2 MINI low-capacity nitrogen generator for nitrogen generation

Autoclave-Safe Medical Sterile Filters

Our medical sterile filters, equipped with stainless steel element endcaps, are 100% integrity tested and provided with an Air Sterilization Certificate for guaranteed high-quality air.

Image of GMS Sterile Air Filter

Absolute Sterile Air Membrane Filters for Critical Processes

nano sterile membrane filters deliver superior microbial and particulate retention for compressed air and gas, exceed SQF standards, and support food, beverage, biotech, and sterile applications.

A stainless steel sterile air membrane process filter with its element

Related Blogs

Customer Stories

CO₂ Removal Solution for Ontario University Laser Lab | nano Canada

Learn how a leading Canadian university achieved ultra‑pure compressed air, lowering CO₂ levels below 1 ppm and reaching a −70°C dew point, using nano’s NDC Lab Gas CO₂ Removal Dryer to boost laser system performance and reduce maintenance needs.
Two people in protective equipment working in a lab with a shelf of bottles in from of them.

Let's Connect

Get world-class experience with nano today. 

Abstract polygonal space background blue with connection lines and dots.