These models were developed for laboratories, so these units require no bench space, can be wall mounted, and ensure quiet operation with a novel exhaust silencer.
Key Specs:
Flow Rate
2.5 to 200 I/min
Connection
⅜” to 1” BSPP
Air Quality
CO2 levels of less than 1 ppm
Product Documentation
- Brochures
- Certificates
- Electrical Diagrams
- General Arrangement Drawings
- Material Safety Data Sheets
- User Guides
NDC 015-600 CO2 Removal Dryers
General Arrangement Drawing
Features
Each model requires less than 15 minutes for maintenance due to unique factory built-in filtration and adsorption cartridges.
PLC Controller with clear text display as standard.
Specifications of our models
Dryer Model |
Recommended Filtration |
Inlet & Outlet |
Inlet Air Flow at 7 barg | Outlet Gas FLow |
---|---|---|---|---|
Part no. |
BSPP |
l/min |
l/min |
|
NDC 015 |
GFNB 0025 |
3/8” |
2.5 |
1.5 |
NDC 050 |
GFNB 0025 |
⅜” |
8.3 |
5.0 |
NDC 140 |
GFNB 0025 |
3/8” |
25 |
15 |
NDC 300 |
GFNB 0025 |
⅜” |
50 |
30 |
NDC 600 |
GFNB 0025 |
½” |
100 |
60 |
NDC 900 |
GFNB 0050 |
1” |
150 |
90 |
NDC 1200 |
GFNB 0050 |
1” |
200 |
120 |
Outlet Gas Quality |
Standard |
Optional |
---|---|---|
Maximum CO2 content |
1 ppm |
- |
Maximum pressure dew point |
-70°C |
- |
Maximum particulate size |
1 micron |
0.01 micron |
Maximum oil content |
- |
0.003 ppm |
Specifications |
||
---|---|---|
Design operating pressure range |
4 to 12 barg |
|
Recommended operating temperature range |
1.5 to 20°C |
|
Power supply requirements |
85 to 264V AC (50/60Hz) |
|
Maximum noise level (during purge) |
60 dBa |
(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.