Can be supplied and directly mounted to nano filtration to ensure process air is clean
55 to 702 scfm
½” to 3” NPT(F)
0.01 micron
Compact solid-state temperature controller is mounted on top of the unit and the exact temperature output is indicated by a bi-metallic thermometer
Uses an open wound heating coil and high accuracy output temperature sensing device
Filter Model |
Replacement Element |
Inlet & Outlet |
Rated Flow (1) |
|
Part No. |
NPT(F) |
scfm |
Nm3/h |
|
PF 0085 SM-N |
E 102 SM |
½” |
55 |
93 |
PF 0120 SM-N |
E 102 SM |
¾” |
60 |
102 |
PF 0170 SM-N |
E 105 SM |
1” |
102 |
173 |
PF 0460 SM-N |
E 110 SM |
2” |
235 |
399 |
PF 0850 SM-N |
E 120 SM |
2 ½” |
468 |
795 |
PF 1150 SM-N |
E 130 SM |
3” |
702 |
1193 |
Specifications |
Standard |
Optional |
Design Operating Pressure Range |
0 to 232 psig / 0 to 16 bar |
- |
Inlet & Outlet Connections |
NPT(F) |
tri-clamp sanitary |
Drain & Vent Connections |
1/4” BSPP |
- |
Element Performance |
SM |
Particle Removal (at 100% PTFE Membrane) |
0.01 Micron |
Continuous Operating Temperature Range |
35 to 120°F / 2 to 49°C |
Maximum Sterilizing Temperature (3) |
257°F / 125°C |
Media Material |
Hydrophobic PTFE Membrane |
Media Support & Endcap Material |
Polypropylene |
Element to Housing Connection |
Positive Click Lock with Dual Silicone O-Rings |
(1) at 100 psig. For all other pressures, refer to the pressure correction factors above
(2) +/- 0.118”
(3) at 30 psia for 20 minutes. Apples to element only
(4) validation documents available upon request
(5) not for use in air or gas streams containing water or oil
(6) all materials conform to 21CFR Part 177 of the US code of Federal Regulations and USP Class VI Biological test for plastics
(7) air flow from outside to inside
(8) technical specifications subject to change without notice.