Constructed with an oleophobic borosilicate microfiber media with an open cell reticulated foam prefilter.
Key specs:
FREE ASPIRATED AIR
1.7 to 212 Nm3/h
Connection
¼” to 3” BSPP
Filtration
0.01 micron
Product Documentation
- Brochures
- User Guides
Features
“Dead Stop” bowl feature provides full closure without over tightening.
Housing manufactured from cast aluminium alloy providing enhanced strength and feature an E-Coat™ finish for optimum internal and external corrosion protection.
Specifications of Our Models
Medical Vacuum Filter Model |
Replacement Element | Inlet & Outlet | Free Aspirated Air at 0.63 bara | Rarifed Air Flow |
---|---|---|---|---|
Part No. | BSPP | Nm3/h | Nm3/h | |
GMVB 0025 | GE 0032 MV | ¼” | 1.7 | 3.4 |
GMVB 0032 | GE 0032 MV | ⅜” | 3.4 | 6.8 |
GMVB 0050 | GE 0050 MV | ½” | 6.8 | 17 |
GMVB 0070 | GE 0105 MV | ½” | 12 | 31 |
GMVB 0085 | GE 0105 MV | ¾” | 14 | 37 |
GMVB 0105 | GE 0105 MV | 1" | 17 | 44 |
GMVB 0175 | GE 0175 MV | 1" | 29 | 77 |
GMVB 0280 | GE 0325 MV | 1 ¼” | 58 | 151 |
GMVB 0325 | GE 0325 MV | 1 ½” | 63 | 167 |
GMVB 0450 | GE 0450 MV | 2" | 66 | 175 |
GMVB 0700 | GE 0700 MV | 2" | 93 | 246 |
GMVB 0850 | GE 0900 MV | 2 ½” | 158 | 418 |
GMVB 0900 | GE 0900 MV | 3" | 180 | 476 |
GMVB 1250 | GE 01250 MV | 3" | 201 | 532 |
GMVB 1500 | GE 1500 MV | 3" | 212 | 562 |
Specifications |
GMVB 0025 to GMVB 0050 |
GMVB 0070 to GMVB 1500 |
---|---|---|
Design operating pressure range |
FV to 0.5 barg |
FV to 0.5 barg |
Design operating temperature range | 1.7 to 60°C | 1.7 to 60°C |
Condensate drain |
GFMDKB 0050 | GFMDKB 1500 |
Differential pressure gauge |
- | GVDP 1500 |
Differential pressure indicator |
GVDP 0050 | - |
Element Performance |
MV |
---|---|
Maximum particle size (ISO class) |
> 99.9999% (HTM 02-01 specifies > 99.995%) |
Pressure drop - clean |
≤ 0.39 barg |
Maximum element life |
6 months or 1000 hours |
(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.
Frequently Asked Questions
Not all medical vacuum filters are universally compatible with different vacuum systems. The type of filter required depends on the specific vacuum system and its intended application. Be sure to choose a filter designed for your specific vacuum system (e.g., portable, central, or wall-mounted systems).
Using the wrong medical vacuum filter can lead to inadequate filtration, which could contaminate the medical environment, inefficient vacuum performance, or even damage the vacuum system. Always choose filters that meet your system's specifications and are certified for medical use.
Medical vacuum filters must handle the airflow or flow rate required by your vacuum system without causing excessive pressure drop or reducing vacuum efficiency. Ensure the filter matches the specifications of your vacuum system to maintain optimal performance.
The right medical vacuum filter depends on several factors, including the type of vacuum system you have, the specific contaminants you need to filter, and the flow rate of your system. Ensure the filter is compatible with your system’s specifications and meets the required filtration standards for medical use.
Our GMVB medical vacuum filters are designed to remove various contaminants, including airborne particles, bacteria, viruses, dust, oil vapours, and moisture. This ensures the vacuum system remains clean and operates efficiently without contaminating medical environments.
The GMVB range has a micron rating of 0.01 or >99.9999%, indicating the size of particles the filter can capture. The HTM 02-01 standard specifies a filtration efficiency of >99.995%, meaning the GMVB medical vacuum filter range exceeds this requirement.
The drain flask is easily removable and can be sterilised for repeated use.
The design operating pressure range is FV to 0.5 barg. The pressure rating indicates the maximum vacuum pressure the filter can withstand without collapsing or being damaged. Ensure that the filter is rated to handle the vacuum pressures used in your system to maintain efficiency and avoid potential system failure.
Yes, our filters are designed to meet the highest industry standards, including ISO 7396-1, HTM 02-01, and the 2018 revision of NFPA (5.1.3.7.4), making them the go-to choice for dental, medical, and veterinary applications.
nano GMVB filter housings are made from die-cast aluminium alloy and feature a durable powder-coated exterior. They also have an internal and external E-Coat™ finish for superior corrosion resistance. The filter element is constructed from an oleophobic borosilicate microfiber media with an open-cell reticulated foam prefilter.
Installation typically involves connecting the filter to the vacuum system according to the manufacturer’s instructions. Ensure the filter is securely installed and fits the designated space for optimal performance. Consult the product manual for detailed installation steps.
The filters require regular maintenance to function correctly—contact nano for the maintenance schedule.
The filter element should be replaced every 6 months or 1000 hours.
The cost varies depending on the size required for your compressed air system.
nano GMVB housing: 10 years from the date of shipment. All other components: 18 months from the date of shipment (from the factory) or 12 months from the date of installation/start-up, whichever occurs first • Coverage: 100% parts only