This range provides a typical return on investment of less than 24 months
Key Specs:
Purity
95 to 99.999%
Flow Rate
up to 101, 400 scfh
Max Allowable Working Pressure
145 psig
Product Documentation
- Brochures
- Certificates
- Electrical Diagrams
- Flow Diagrams
- GA Drawings
- Material Safety Data Sheets
- Technical Paper
- User Guides
- Worksheet
Features
Eco-mode energy savings control reduces energy consumption during periods of low demand resulting in significant reduction of operational cost
Vision01 PLC/HMI controlled operation provides maximum reliability with a touch screen interface
Specifications of our models
Generator Model |
Rated Outlet |
Nitrogen Purity at the Outlet (Max Oxygen Content) |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
99.999% |
99.99% |
99.95% |
99.9% |
99.5% |
99% |
98% |
97% |
96% |
95% |
||
scfh |
(10 ppm) |
(100 ppm) |
(500 ppm) |
(0.10%) |
(0.50%) |
(1%) |
(2%) |
(3%) |
(4%) |
(5%) |
|
scfh |
1620 |
2420 |
3119 |
4093 |
5556 |
6496 |
7946 |
8998 |
10012 |
11049 |
|
scfh |
2037 |
3042 |
3921 |
5145 |
6984 |
8166 |
9988 |
11311 |
12585 |
13888 |
|
scfh |
2520 |
3960 |
5160 |
6720 |
9360 |
11100 |
13560 |
15720 |
17460 |
19320 |
|
scfh |
3240 |
5040 |
6600 |
8640 |
12120 |
14340 |
17460 |
20220 |
22500 |
24900 |
|
scfh |
3960 |
6120 |
8040 |
10500 |
14700 |
17400 |
21240 |
24540 |
27360 |
30240 |
|
scfh |
4500 |
6960 |
9120 |
11880 |
16620 |
19680 |
24000 |
27780 |
30960 |
34260 |
|
scfh |
5460 |
8520 |
11100 |
14520 |
20400 |
24060 |
29400 |
34020 |
37920 |
41940 |
|
scfh |
6540 |
10200 |
13320 |
17400 |
24360 |
28800 |
35220 |
40680 |
45360 |
50160 |
|
scfh |
8220 |
12780 |
16680 |
21840 |
30540 |
36120 |
44100 |
51000 |
56760 |
62880 |
|
scfh |
10440 |
16200 |
21180 |
27660 |
38760 |
45840 |
55920 |
64680 |
72060 |
79740 |
|
scfh |
13260 |
20640 |
26880 |
35160 |
49260 |
58260 |
71100 |
82260 |
91620 |
101400 |
Specifications |
Standard |
Optional |
---|---|---|
Design operating pressure range |
72.5 to 145 psig |
- |
Design operating temperature range |
41 to 122°F |
4 to 122°F |
Recommended operating temperature range |
41 to 95°F |
- |
Maximum inlet particulate |
0.1 micron |
- |
Maximum inlet oil content |
0.01 micron |
- |
Maximum inlet dew point |
38°F PDP |
- |
Supply voltage |
100 - 240 VAC (50 or 60Hz) |
- |
(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.