High performance valves designed for durability, ease of maintenance and long service life.
Key Specs:
Flow Rate
3 scfm and up
Connection
⅜” PTC to 2 ½” NPT (F)
Air Quality
ISO 8573.1:2010 Class 1.2.2
Product Documentation
- Brochures
- Certificates
- Electrical Diagrams
- General Arrangement Drawings
- Material Safety Data Sheets
- P & ID
- Service Intervals
- Spare Parts Guide
- Service Manuals
- Technical Papers
- User Guides
- Worksheets
Features
Patented, high density snowstorm filled cartridges (models NDL 010 to NDL 130) with integrated after filter (all models) can be serviced in less than 15 minutes and provide maximum adsorption capacity.
Energy-saving dew point control and a -94°F pressure dew point are optional features available on all models, from NDL 010 to NDL 6130. The advanced PLC controller option is only available for models NDL 2110 through NDL 6130.
Specifications of Our Models
Desiccant Dryer Model |
Prefilter (1 micron) | Integrated Afterfilter |
Inlet & Outlet |
Rated Flow at 100 psig |
|
|---|---|---|---|---|---|
| Part No. | Part No. | Part No. | PTC/NPT (F) |
scfm |
|
D1 |
|||||
| - | standard |
⅜” PTC |
3 |
||
| - | standard |
⅜” PTC |
5 |
||
| - | standard |
⅜” PTC |
10 |
||
| - | standard |
⅜” PTC |
15 |
||
| - | standard |
½” PTC |
20 |
||
D2 |
|||||
| - | standard |
1” |
34 |
||
| - | standard |
1” |
41 |
||
| - | standard |
1” |
53 |
||
| - | standard |
1” |
66 |
||
| - | standard |
1” |
88 |
||
| - | standard |
1” |
106 |
||
| - | standard |
1” |
132 |
||
| - | standard |
1” |
177 |
||
D3 |
|||||
| GFN 0450 M1 |
standard |
2” |
212 |
||
| GFN 0450 M1 | standard |
2” |
276 |
||
| GFN 0450 M1 | standard |
2” |
400 |
||
| GFN 0700 M1 | standard |
2” |
560 |
||
| GFN 0850 M1 | standard |
2 ½” |
750 |
||
| GFN 0850 M1 | standard |
2 ½” |
828 |
||
| GFN 1250 M1 | standard |
2 ½” |
1110 |
||
| Specifications | D1 & D2 |
D3 |
||
|---|---|---|---|---|
Standard |
Optional |
Standard |
Optional |
|
Maximum particle size (ISO class) |
class 2 (1 micron) |
class 1 |
class 2 (1 micron) |
class 1 (0.01 micron) |
Maximum water content (ISO class) |
class 2 (-40°F) |
lass 1 (-94°F pdp) |
class 2 (-40°F pdp) |
class 1 (-94°F) |
Minimum operating pressure |
58 psig |
- |
58 psig |
- |
Maximum operating pressure |
232 psig |
- |
145 psig |
232 psig (consult factory) |
Recommended operating temp range |
35 to 85°F |
- |
35 to 100°F |
- |
Design operating temperature range |
35 to 100°F |
- |
35 to 122°F |
- |
Power supply requirements |
100 to 240 VAC / 50 or 60 Hz |
pneumatic or 24 V DC |
100 to 240 VAC / 50 or 60 Hz |
pneumatic or 24 V DC |
(1) This information is for general information purposes only. For additional technical specifications, refer to the product brochure, technical data sheets, and/or user guides. Technical specifications are subject to change.